The Latest from the Energy Vanguard Blog

New home installation with sagging flex duct
Posted by Allison Bailes on June 23, 2016
Last month while I was in Austin, homebuilder extraordinaire Matt Risinger gave me a tour of some of his projects. Afterward I wrote about something I saw on his new home construction site that was a sign of a good duct installer. Today I bring you a few photos that are signs of a bad duct...
24 Comments | Read/write comments
interstitial-pressure-field-mad-air-leakage.jpg
Posted by Allison Bailes on May 25, 2016
The word "interstitial" comes up occasionally in building science discussions. I think I've heard it a couple of times at conferences just in the past month. That may be because Joe Lstiburek was there. He's the guy who used that word 127 times in his doctoral dissertation, Toward an Understanding...
15 Comments | Read/write comments
duct-fittings-pre-insulated-sealed-mastic.jpg
Posted by Allison Bailes on May 9, 2016
Matt Risinger is a home builder in Austin. He builds great houses and is also famous for his videos. He has over 26 thousand subscribers on his Youtube channel. I was in Austin last week for the inaugural Humid Climate Conference and had some extra time on Saturday morning. So I got a tour of a few...
26 Comments | Read/write comments
flex-duct-downspout-retrofit-stephen-morrison.jpg
Posted by Allison Bailes on February 24, 2016
When Stephen Morrison of MoreSun Custom Woodworking sent me the photo below, my reaction was, Wow! Just wow! This duct retrofit is absolutely stunning. It's an elegant display of creativity unhindered by knowledge. Can you see what they've done?
22 Comments | Read/write comments
air conditioner ducts outdoors
Posted by Allison Bailes on February 3, 2016
I love me some good bad photos. You know, good photos of bad stuff. If you've been here a while, you've seen some of the doozies I've posted in the Energy Vanguard Blog. Take Stumpy, the duct amputee or Release the Kraken or the ice chest in the duct system or any of a number of building enclosure...
6 Comments | Read/write comments
E3-cool-air-intake-crawl-space-1-600.jpg
Posted by Allison Bailes on February 1, 2016
I know it's not air conditioning season, but this story is too good to wait until summer rolls around. My friends at E3 Innovate in Nashville — you may remember them for finding the home ventilated with dead possum odors — have done it again. This time they've discovered a crawl space with an...
9 Comments | Read/write comments
garage-ventilation-indoor-air-quality.jpg
Posted by Allison Bailes on January 15, 2016
If you have an attached garage where you live, the odds are high that your indoor air quality is worse than a home without an attached garage. Just take a look at the photo below to see some of the sources of pollutants that can get into your home's air. How many do you see?
6 Comments | Read/write comments
Posted by Allison Bailes on October 27, 2015
Boilers for heating homes are common in some areas. Not here in Georgia, where I live, but my friends in the colder climates have them. This type of heating equipment takes a fuel like natural gas or fuel oil, burns it to create heat, and then puts that heat into water circulating through the...
8 Comments | Read/write comments
hvac-duct-flex-poorly-supported-reduced-airflow-energy-vanguard
Posted by Allison Bailes on September 16, 2015
Sagging flex duct is bad for air flow. We all know it. We all talk about it. It turns out there's research data to prove it, too. Texas A&M did a study a few years ago to look at the pressure drop that occurs for different levels of compression. If you're not familiar with this study, the...
10 Comments | Read/write comments
hot-dark-roof-infrared-image
Posted by Allison Bailes on August 26, 2015
The most contentious issue I’ve written about since I started blogging isn’t bad Manual Js. Nor is it endorsing government intervention by raising efficiency standards or improving energy codes. Incredibly, it’s not even whether or not naked people need building science. Nope. The topic that really...
35 Comments | Read/write comments

Pages

Subscribe to the Energy Vanguard Blog